|本期目录/Table of Contents|

[1]聂桂波,徐卫丹,马加路,等.电机设备三维隔震试验研究[J].地震研究,2024,47(01):156-162.[doi:10.20015/j.cnki.ISSN1000-0666.2024.0005]
 NIE Guibo,XU Weidan,MA Jialu,et al.Three-dimensional Isolation Test of the Motor Equipment[J].Journal of Seismological Research,2024,47(01):156-162.[doi:10.20015/j.cnki.ISSN1000-0666.2024.0005]
点击复制

电机设备三维隔震试验研究(PDF/HTML)

《地震研究》[ISSN:1000-0666/CN:53-1062/P]

卷:
47
期数:
2024年01期
页码:
156-162
栏目:
出版日期:
2024-01-01

文章信息/Info

Title:
Three-dimensional Isolation Test of the Motor Equipment
作者:
聂桂波徐卫丹马加路王志詠石宇杰
(中国地震局工程力学研究所 地震工程与工程振动重点实验室,黑龙江 哈尔滨150080)
Author(s):
NIE GuiboXU WeidanMA JialuWANG ZhiyongSHI Yujie
(Key Laboratory of Earthquake Engineering and Engineering Vibration,Institute of Engineering Mechanics,China Earthquake Administration,Harbin 150080,Heilongjiang,China)
关键词:
电机设备 隔震支座 振动台试验 隔震效率
Keywords:
motor equipment seismic isolation shaking table test seismic isolation efficiency
分类号:
TU352.1
DOI:
10.20015/j.cnki.ISSN1000-0666.2024.0005
摘要:
针对核电设备设计研制了三维隔震支座,以核电设备常用的电机为例,对其三维隔震性能开展了振动台试验研究,获得了电机设备典型部位的隔震动力响应,通过对比振动台台面数据与设备测点位置的数据来验证隔震支座的隔震效果。结果表明:随着输入地震动峰值增大,隔震支座的隔震效率差别微小,隔震效果比较稳定,说明隔震支座对电机设备起到了良好的隔震作用。
Abstract:
A three-dimensional seismic isolation bearing is designed for the nuclear power equipment.Taking the commonly used motor of nuclear power equipment as an example,we carried out a shaking table test to investigate the performance of three-dimensional seismic isolation of the motor and to obtain the seismic dynamic response of typical parts of the equipment.By comparing the data of the shaking table with the data of the measuring points on the equipment,we confirmed the effect of the seismic isolation bearing.The results show that with the increase of the peak value of the input ground motion,the difference in the isolation efficiency of the isolation bearing is small,and the isolation effect is relatively stable,indicating that the isolation bearing plays a good role in isolating the motor equipment.

参考文献/References:


程永锋,朱全军,卢智成.2008.变电站电力设施抗震措施研究现状与发展趋势[J].电网技术,32(22):84-89.
Cheng Y F,Zhu Q J,Lu Z C.Progress and development trend on seismic measures of electric power equipment in transformer substation[J].Power System Technology,32(22):84-89.(in Chinese)
郭永基.2001.电力系统及电力设备的可靠性[J].电力系统自动化,(17):53-56.
Guo Y J.2001.Reliability of power systems and power equipment[J].Automation of Electric Power Systems,(17):53-56.(in Chinese)
胡珍秀.2020.电力设施地震韧性评估方法研究[D].哈尔滨:中国地震局工程力学研究所.
Hu Z X.2020.Study on seismic resilience evaluation method of power facilities[D].Harbin:Institute of Engineering Mechanics,China Earthquake Administration.(in Chinese)
刘中华.2008.核电设备抗震试验与计算分析[D].上海:同济大学.
Liu Z H.2008.Seismic testing and analysis of equipment for NPP[D].Shanghai:Tongji University.(in Chinese)
宁晓晴.2014.考虑机械振动的风机设备两种隔震方案对比研究[D].哈尔滨:中国地震局工程力学研究所.
Ning X Q.2014.Comparative study on two kinds of isolation schemes for the fan equipment considering mechanical vibration[D].Harbin:Institute of Engineering Mechanics,China Earthquake Administration.(in Chinese)
滕艳玲.2010.核电站用三相异步电动机[J].电机技术,128(3):28-31.
Teng Y L.2010.Three-phase asynchronous motor for nuclear power station[J].Electrical Machinery Technology,128(3):28-31.(in Chinese)
王涛,王飞,侯钢领,等.2014.核电厂隔震结构的振动台试验研究[J].工程力学,31(10):62-68,84.
Wang T,Wang F,Hou G L,et al.2014.Shaking table tests on base-isolated nuclear power plant[J].Engineering Mechanics,31(10):62-68,84.(in Chinese)
魏陆顺,周福霖,任珉,等.2007.三维隔震(振)支座的工程应用与现场测试[J].地震工程与工程振动,27(3):121-125.
Wei L S,Zhou F L,Ren M,et al.2007.Application of three-dimensional seismic and vibration isolator to building and site test[J].Journal of Earthquake Engineering and Engineering Dynamics,27(3):121-125.(in Chinese)
姚堃,钱江.2017.特高压电力设备隔震技术研究[C]//陆新征.第26届全国结构工程学术会议论文集(第Ⅲ册).哈尔滨:《工程力学》杂志社,283-287.
Yao K,Qian J.2017.Research on isolation technology of uhvelectrical equipment[C]//Lu X Z,Proceedings of the 26th national conference on structural engineering(No.III).Harbin:Engineering Mechanics Periodical Office,283-287.(in Chinese)
尤红兵,张郁山,赵凤新.2012.电气设备振动台试验输入的合理确定[J].电网技术,36(5):118-124.
You H B,Zhang Y S,Zhao F X.2012.Reasonable determination of input waves for shake-table test of electrical equipments[J].Power System Technology,36(5):118-124.(in Chinese)
GB 50011—2010,建筑抗震设计规范[S].
GB 50011—2010,Code for seismic design of buildings[S].(in Chinese)
GB 50260—2013,电力设施抗震设计规范[S].
GB 50260—2013,Code for seismic design of electrical installations[S].(in Chinese)
SY 4063—1993,电气设施抗震鉴定技术标准[S].
SY 4063—1993,Standard for earthquake pesistance valuation of electric facilities[S].(in Chinese)

备注/Memo

备注/Memo:
收稿日期:2023-03-14
基金项目:黑龙江省自然科学基金杰出青年基金(JQ2022E006); 中国地震局工程力学研究所基本科研业务费专项(2021B01); 中国地震局地震工程与工程振动重点实验室重点专项(2021EEEVL0308).

更新日期/Last Update: 2023-12-20