|本期目录/Table of Contents|

[1]张俊杰,刘如山,吴 萌,等.输电线路抗震韧性评估方法研究[J].地震研究,2024,47(01):10-17.[doi:10.20015/j.cnki.ISSN1000-0666.2024.0003]
 ZHANG Junjie,LIU Rushan,WU Meng,et al.Research on the Seismic Resilience Assessment Method of Power Lines[J].Journal of Seismological Research,2024,47(01):10-17.[doi:10.20015/j.cnki.ISSN1000-0666.2024.0003]
点击复制

输电线路抗震韧性评估方法研究(PDF/HTML)

《地震研究》[ISSN:1000-0666/CN:53-1062/P]

卷:
47
期数:
2024年01期
页码:
10-17
栏目:
出版日期:
2024-01-01

文章信息/Info

Title:
Research on the Seismic Resilience Assessment Method of Power Lines
作者:
张俊杰刘如山吴 萌洪一翔
(中国地震局工程力学研究所 地震工程与工程振动重点实验室,黑龙江 哈尔滨 150080)
Author(s):
ZHANG JunjieLIU RushanWU MengHONG Yixiang
(Key Laboratory of Earthquake Engineering and Engineering Vibration,Institute of Engineering Mechanics,China Earthquake Administration,Harbin 150080,Heilongjiang,China)
关键词:
输电线路 抗震韧性 易损性 功能失效 恢复时间
Keywords:
transmission lines seismic resilience vulnerability functional failure recovery time
分类号:
TM726; TU317
DOI:
10.20015/j.cnki.ISSN1000-0666.2024.0003
摘要:
输电线路抗震韧性研究有助于确定震后输电线路功能损失和恢复时间,为震后电力系统恢复提供重要参考。基于2008年汶川8.0级地震后成都、绵阳、德阳、广元和阿坝5个地区的输电线路震害资料,分析了输电线路功能失效、恢复情况,建立了功能失效、恢复时间与破坏情况的对应关系函数,结合韧性定义给出输电线路功能损失累积函数,划分了韧性水平等级,形成了以电压等级、长度、地形地貌为参数的输电线路抗震韧性计算方法。使用该方法对我国某地区输电线路进行试算,计算结果与以往对输电线路震害情况的定性判断基本相符,能够揭示出该地区输电线路在低烈度时损失较轻、在高烈度时损失较重的基本规律。
Abstract:
Seismic resilience study helps to assess the functional loss and the recovery time of the transmission lines.It also provides a reference for post-earthquake recovery of the power system.Based on the data of the seismic damage to the transmission lines in regions like Chengdu,Mianyang,Deyang,Guangyuan and Aba after the Wenchuan MS8.0 earthquake in 2008,the functional failure and recovery of the transmission lines are studied.The correlation function between the functional failure and the damage to the transmission lines is built.The correlation function between the recovery time and the damage to the transmission lines is built too.On the basis of the definition of the resilience,the functional cumulative loss function of the transmission lines was established.Then the seismic resilience ranks are put forward.A method to calculating the seismic resilience of the transmission lines is developed,which involves voltage and length of the transmission lines,and topography of the areas which the transmission lines go through.The method proposed in this paper is applied to the calculation of the seismic resilience of the transmission lines in an earthquake-stricken area,and the results are generally consistent with the post-earthquake,field investigation of the seismic damage to the transmission lines.This proves that in mountainous areas the transmission lines would suffer less losses when hit by low intensity ground motion,and would suffer more losses when hit by high intensity ground motion.

参考文献/References:


毕熙荣,冀昆,宗成才,等.2020.工程抗震韧性定量评估方法研究进展综述[J].地震研究,43(3):417-430.
Bi X R,Ji K,Zong C C,et al.2020.Review on advances in quantitative evaluation methods for engineering seismic resilience[J].Journal of Seismological Research,43(3):417-430.(in Chinese)
贺海磊,郭剑波,谢强.2011.电气设备的地震灾害易损性分析[J].电网技术,35(4):25-28.
He H L,Guo J B,Xie Q.2011.Vulnerability analysis of power equipments caused by earthquake disaster[J].Power System Technology,35(4):25-28.(in Chinese)
李宏男,白海峰.2007.高压输电塔-线体系抗灾研究的现状与发展趋势[J].土木工程学报,40(2):39-46.
Li H N,Bai H F.2007.State-of-the-art review on studies of disater resistance of high-voltage transmission tower-line systems[J].China Civil Engineering Journal,40(2):39-46.(in Chinese)
林均岐,陈永盛,刘金龙.2011.电力系统震后网络连通性研究[J].地震工程与工程振动,31(6):181-185.
Lin J Q,Chen Y S,Liu J L.2011.Study on post-earthquake connectivity of electric power systems[J].Journal of Earthquake Engineering and Engineering Vibration,31(6):181-185.(in Chinese)
刘如山,刘金龙,颜冬启,等.2013.芦山7.0级地震电力设施震害调查分析[J].自然灾害学报,22(5):83-90.
Liu R S,Liu J L,Yan D Q,et al.2013.Seismic damage investigation and analysis of electric power system in Lushan MS7.0 Earthquake[J].Journal of Natural Disasters,22(5):83-90.(in Chinese)
刘如山,张美晶,邬玉斌,等.2010.汶川地震四川电网震害及功能失效研究[J].应用基础与工程科学学报,18(S1):200-211.
Liu R S,Zhang M J,Wu Y B,et al.2010.Damage and failure study of Sichuan electric power grid in Wenchuan earthquake[J].Journal of Basic Science and Engineering,18(S1):200-211.(in Chinese)
谢华飞.2011.地震灾害对电网的损毁性评估技术研究[D].杭州:浙江大学.[LL]Xie H F.2011.Research on damage assessment to electrical grid caused by earthquake[D].Hangzhou:Zhejiang University.(in Chinese)
谢强.2008.电力系统的地震灾害研究现状与应急响应[J].电力建设,29(8):1-6.
Xie Q.2008.State-of-the-art of seismic disaster research and emergency response of electric power system[J].Electric Power Construction,29(8):1-6.(in Chinese)
翟长海,刘文,谢礼立.2018.城市抗震韧性评估研究进展[J].建筑结构学报,39(9):1-9.
Zhai C H,Liu W,Xie L L.2018.Progress of research on city seismic resilience evaluation[J].Journal of Building Structures,39(9):1-9.(in Chinese)
张中近.2017.电力设施地震经济损失快速评估[D].哈尔滨:中国地震局工程力学研究所.
Zhang Z J.2017.Rapid evaluation of electric power facility economic loss caused by earthquake[D].Harbin:Institute of Engineering Mechanics.(in Chinese)
DL/T 741—2019,架空输电线路运行规程[S].
DL/T 741—2019,Operating code for overhead transmission line[S].(in Chinese)
GB/T 24336—2009,生命线工程地震破坏等级划分[S].
GB/T 24336—2009,Classification of earthquake damage to lifeline engineering[S].(in Chinese)
ATC.1991.ATC25 Seismic vulnerability and impact of disruption of lifelines in the conterminous United States[R].Advanced Technology Council.
Bruneau M,Chang S E,Eguchi R T,et al.2003.A framework to quantitatively assess and enhance the seismic resilience of communities[J].Earthquake spectra,19(4):733-752.
FEMA.2013.Multi-hazard loss estimation methodology,earthquake model,Hazus-MH 2.1,technical manual[R].Washington D C,USA.
Ghorani R,Fattaheian-Dehkordi S,Farrokhi M,et al.2021.Modeling and quantification of power system resilience to natural hazards:A case of landslide[J].IEEE Access,9:80300-80309.
Omar K,Paolo C G,Mahin S A.2018.Downtime estimation and analysis of lifelines after an earthquake[J].Engineering Structures,173:393-403.
Ouyang M.2014.Review on modeling and simulation of interdependent critical infrastructure systems[J].Reliability Engineering & System Safety,121(1):43-60.
Ouyang M,Due?as-Osorio L,Min X.2012.A three-stage resilience analysis framework for urban infrastructure systems[J].Structural Safety,36-37:23-31.
Pearson K.1992.On the criterion that a given system of deviations from the probable in the case of a correlated system of variables is such that it can be reasonably supposed to have arisen from random sampling[M]//Springer Series in Statistics,11-28.
Reed D A,Kapur K C,Christie R D.2009.Methodology for assessing the resilience of networked infrastructure[J].IEEE Systems Journal,3(2):174-180.

备注/Memo

备注/Memo:
收稿日期:2023-03-14
基金项目:国家自然科学联合基金重点项目(U2239252); 中国地震局工程力学研究所基本科研业务费专项(2021EEEVL0315).

更新日期/Last Update: 2023-12-20